Skip to content

IEC 60320 Adapter Cords

10–20 Amps125–250 voltsRoHSULcULREACH

Reference guide:IEC 60320 connector guide →

21

configurations

Not sure which cord you need?

Answer a few quick questions and we’ll narrow it down for you.

Match by picture

About IEC 60320 Adapter Cords

Drawbacks/Considerations when using Twist Lock Adapter Cables.

When manufacturers design the power cable that will supply the power for their equipment, generally they will select a specific configuration with intent so that the end user will not have to. This includes technical requirements like amperage and voltage, but also considerations like standard or locking power connections. When equipment utilizes a twist locking plug it is because the equipment draws high power, is used in a high traffic or industrial environment, and would be a substantial inconvenience or even detrimental if it were unplugged accidentally. When you use an iec to twist lock adapter cable, you are essentially removing that layer of intent put in place by the manufacturer. The cable will still supply adequate power for your equipment which is all that really matters, but the extra precaution of a secure connection is removed.

Will my NEMA 5-15R Work from an IEC C14 Rackmount PDU?

We offer both Twist Lock Adapters and NEMA Adapters that will allow you to plug in your Nema Power Cables into an IEC 320 Rackmount PDU. Sometimes you will need to charge a laptop, or power a monitor and the only power source you have available is IEC320 PDUs in your Data Center or IT Closet. Luckily, we stock several configurations in many lengths to help save the day when you are trouble shooting your gear.

IEC to NEMA Adapter Cables are used in these types of locations.

NEMA or National Electrical Manufacturers Association is the collective interest of manufacturers creating electrical products used in North America, so these adapter cables will only be found in North America. Furthermore, these cables are used to provide a NEMA power source where one is not present and only IEC320 Outlets are. This generally only occurs in places where there is a PDU designed for IT equipment, for example, IT closets in large office buildings and data centers where power supplies are designed for specific equipment instead of human conveniences.

The plugs and connectors in this collection

What each end is, what it mates with, and where to find every cord built on it.

  • IEC 60320 C14 plug

    Plug · IEC 60320

    IEC 60320 C14

    • 15 Amps
    • 250 volts

    On 19 of the cords here (90%)

    The IEC 60320 C14 is a grounded 3 Wire Plug rated up to 250V and 15 Amps. The C14 mates with a C13 outlet, typically found on Data Center/IT specific PDUs (Power Distribution Unit). The most common configuration for a C14 is in a jumper cable scenario, providing power from a PDU to IT Equipment.

    Mates with IEC 60320 C13 Outlet

  • NEMA 5-15R connector

    Connector

    NEMA 5-15R

    • 15 Amps
    • 125 volts

    On 18 of the cords here (86%)

    The NEMA 5-1R connector mates with a NEMA 5-15P plug (the standard plug used in residential homes in North America. Rated at 125V and 15amps. The NEMA 5-15R connector is typically used in an extension cord or a cable adapter.

    Mates with NEMA 5-15P Inlet

  • IEC 60320 C20 plug

    Plug · IEC 60320

    IEC 60320 C20

    • 20 Amps
    • 250 volts

    On 2 of the cords here (10%)

    The IEC 60320 C20 is a grounded 3 Wire Plug rated up to 250V and 20 Amps. The C20 mates with a C19 outlet, typically found on Data Center/IT specific PDUs (Power Distribution Unit). The most common configuration for a C20 is in a jumper cable scenario, providing power from a PDU to a blade server chassis, high powered server, large network router, or similar device.

    Mates with IEC 60320 C19 Outlet

  • NEMA L6-30R connector

    Connector

    NEMA L6-30R

    • 30 Amps
    • 250 volts

    On 2 of the cords here (10%)

    The NEMA L6-30R (female) is a 3 Wire 3 Blade grounded device with hot-hot-ground wiring and is rated up to 250V AC and 30 Amps. This is a twist-lock device, insert the plug into the connector and turn. Locking cords are typically used in industrial applications to ensure that accidental power loss does not occur due to a loose connection.

    Mates with NEMA L6-30P Inlet

About IEC 60320 Adapter Cords

If you do not have access to a NEMA Twist Lock receptacle to power your matching Plug and cannot have a receptacle installed, you may need a Twist Lock Adapter. These power cables allow you to access power from a standard Power Distribution Unit (PDU), found in office settings and on Server Racks in the form of a Rack Mount PDU. If you need a power tap for your locking Nema plug, these can be a cost-effective solution. We offer both C20 Adapters and C14 Adapters, allowing you to access the majority of power outlets found on Rackmount PDUs.

Current rating

10–20 Amps

Voltage rating

125–250 volts

Certifications & compliance

  • RoHS
  • UL
  • cUL
  • REACH
  • Every cord we build is hi-pot tested
  • Same-day shipping by 2:30 PM ET
  • NET 30/60/90 for approved accounts
  • In-house engineering and compliance support

Frequently asked questions

What certifications do these power cords carry?
UL and cUL-listed cord sets across the catalog, with 30+ international approval marks (VDE, ENEC, PSE, SAA, CCC, KC and more) on country-specific cords. The approvals each part carries are listed on its product page; documentation is available from sales.
Do you require a minimum order quantity?
No. We sell from 1 cord to 100,000. Volume discounts apply automatically at quantity breaks — you'll see pricing tiers on every product page.
Can I get a custom length or color?
Yes. Custom lengths and non-standard colors are hand-terminated in our Connecticut shop — typically 3–4 business days from in-stock components. Call (860) 763-2100 or submit a quote request with your specs.
How fast does this ship?
In-stock orders placed by 2:30 PM ET ship the same day via FedEx or UPS. All standard configurations are stocked in East Windsor, CT.