Zonit Z-Lock is end of life. Z-Lock+ is its replacement — the same dual-locking cord with colored ID rings and a one-hand release, built here in Connecticut. Remaining Z-Lock stock is listed below.
What changed in Z-Lock Plus™ (Z-Lock+) Locking Power Cords (6)
- Colored ID rings — identify the circuit, feed or rack at a glance instead of tracing cables by hand.
- Integrated sliding-shell release — the shell is the release: a one-hand disconnect replaces the original red tabs.
- Seating line — a visible line confirms the connector is fully engaged.
- Lower-profile nut — sits flush with the housing for tight, high-density outlet spacing.
- Tube labels — clean part identification without rack clutter.
- Built in North America — made on our Connecticut line, with custom lengths, colors, ID rings and labels and no minimum quantity.
Not sure which cord you need?
Answer a few quick questions and we’ll narrow it down for you.
About Zonit Z-Lock Power Cord
Zonit Z-Lock is end of life. Its replacement is Z-Lock Plus™ (Z-Lock+) — the same dual-locking IEC power cord with colored ID rings, a one-hand sliding-shell release and a lower-profile locking nut, built by World Cord Sets in East Windsor, Connecticut. Z-Lock cords already in your racks keep working, and Z-Lock+ locks into the same standard C13/C14 and C19/C20 outlets and inlets, so the two can be mixed as you replace them.
The original Z-LOCK is a universally compatible, dual-locking power cord: it locks C13, C14, C15, C19 and C20 cords on both ends, eliminating accidental disconnects. The remaining Z-Lock stock is listed below.
Looking for a single-sided locking cord? Zonit’s A-LOCK locks on the outlet end, with a standard non-locking input end.
The plugs and connectors in this collection
What each end is, what it mates with, and where to find every cord built on it.
- C14 Locking (Z-Lock)
Plug
IEC 60320 C14 Locking (Z-Lock)
- 15 Amps
- 250 volts
On 43 of the cords here (80%)
The IEC 60320 C14 is a Plug (Male) configuration rated for 250VAC and 15 Amps. The Z-Lock is a universal locking plug type, designed to lock into place by expanding the size of the plug head after insertion by spinning the rotary lock on the plug head.
Mates with IEC 60320 C13 Outlet
You are on the C14 Locking (Z-Lock) family page.

Connector · IEC 60320
IEC 60320 C13 Locking (A-Lock)
- 15 Amps
- 125/250V
On 22 of the cords here (41%)
Mates with IEC 60320 C14 Inlet

Connector
IEC 60320 C15 Locking (A-Lock)
- 15 Amps
- 125/250V
On 15 of the cords here (28%)
Mates with IEC 60320 C16 Inlet

Plug
IEC 60320 C20 Locking (Z-Lock)
- 20 Amps
- 125/250V
On 9 of the cords here (17%)
Mates with IEC 60320 C19 Outlet

Connector · IEC 60320
IEC 60320 C13
- 15 Amps
- 125/250V
On 8 of the cords here (15%)
The IEC 60320 C13 is a grounded 3 Wire connector rated up to 250V and 15 Amps. The C13 mates with a C14 inlet, and is commonly used in a jumper cable scenario in IT Installations providing power from a PDU to a server, router, switch or other computing device. Most people know the C13 as 'the thing that plugs into my computer' because it is the standard connector used to power most desktop computers. In a desktop computer application, the most common cable is the NEMA 5-15P to C13, which connects your standard North American wall outlet to a desktop computer.
Mates with IEC 60320 C14 Inlet

Connector
IEC 60320 C19 Locking (A-Lock)
- 20 Amps
- 125/250V
On 6 of the cords here (11%)
The IEC 60320 C19 Locking Connector is rated for 20 Amps and 250VAC. It is a grounded connector type, with the A-Lock feature for latching the connector in place once it is mated. The A-Lock is a universal locking mechanism that internally pinches the pins of the male/inlet that it connects with. This effectively holds the connector in place until the user pinches and pulls back the two red tabs located on either side of the connector body.
Mates with IEC 60320 C20 Inlet
About Zonit Z-Lock Power Cord
About the original Zonit Z-Lock
Z-LOCK was Zonit’s first dual-locking IEC power cord: a C14 or C20 plug that locks into the PDU outlet and a C13, C15 or C19 connector that locks into the equipment inlet, on standard IEC 60320 receptacles with no special PDU. It shipped in 14 AWG (15 A) and 12 AWG (20 A) builds and several jacket colors.
Moving to Z-Lock+
Z-Lock Plus™ (Z-Lock+) succeeds it with six changes: colored ID rings, an integrated sliding-shell release in place of the red tabs, a visible seating line, a lower-profile nut for dense outlet spacing, tube labels, and North American manufacture on World Cord Sets’ own line in Connecticut. Because both lock into the same standard outlets and inlets, racks can be migrated one cord at a time. Not sure which family fits? Talk to an engineer.
Related
- Z-Lock C14 to C13 15A cords
- Z-Lock C14 to C15 locking cords
- Compare locking power cord systems for your data center
- AI data center power cords — high-density rack solutions
- Same-day shipping on in-stock power cords
How to Choose Between Z-Lock Stock and Z-Lock+
When to buy remaining Z-Lock inventory
Z-Lock is end of life, but the stock listed on this page is new, certified, and ships same day. It is the right choice when:
- You need an exact replacement for an existing Z-Lock cord in a live rack
- Your project requires a specific color (black, red, or blue) or length already in stock
- Budget constraints favor clearance pricing over the upgraded model
When to move to Z-Lock+
Z-Lock+ is the current production model, built in Connecticut on World Cord Sets' own line. Choose it when:
- You are deploying a new rack or refreshing an existing one and want the latest design
- One-hand release and colored ID rings matter for your operations team
- You want a product with an active production run and full OEM/blanket-order support
Migration is straightforward
Because both Z-Lock and Z-Lock+ lock into the same standard IEC 60320 C13 and C19 outlets, you can replace cords one at a time without taking a rack offline. Mixed deployments are fully compatible.
Current rating
10–20 Amps
Voltage rating
250 volts
Certifications & compliance
- UL
- cUL
- Every cord we build is hi-pot tested
- Same-day shipping by 2:30 PM ET
- NET 30/60/90 for approved accounts
- In-house engineering and compliance support
Frequently asked questions
- Can zATS Micro Transfer at any phase angle?
- Yes! zATS Micro can transfer at any phase angle including 180 degrees.
- Is there software that needs to be installed with the zATS?
- No. The zATS is a 1:1 plug-and-play solution that can be deployed in less than 30 seconds.
- What does Zero U mean?
- Zero U means Zero U! The zATS Micro is the size of an iPhone and takes no rack space to connect to your single corded devices.
- What voltage is the zATS Micro rated for?
- There are multiple models. These include a 120 V, 208V and 230 V unit.
- Can I customize the connectors on zATS Micro?
- Yes! There are multiple options for connector sets and lengths available.
- What is the difference between Zonit Z-Lock and Z-Lock+?
- The original Z-Lock uses a rotary nut on the plug head to expand and lock into a standard IEC 60320 outlet, and red-tab A-Lock connectors on the equipment end. Z-Lock+ keeps the same dual-locking principle and mates with the same standard outlets and inlets, but adds:Colored ID rings for circuit identificationAn integrated sliding-shell one-hand release (replacing the red tabs)A visible seating line and lower-profile nut for dense outlet spacingTube labels and North American manufacture in ConnecticutBecause both systems lock into standard IEC 60320 receptacles, racks can be migrated one cord at a time.
- Are Zonit Z-Lock cords UL and cUL listed?
- Yes. The 14 AWG (15 A) and 12 AWG (20 A) SJT builds in this collection carry both UL and cUL certifications. Every cord is also hi-pot tested before it ships. Check individual product listings for the certification marks applicable to a specific SKU.
- What connector combinations are available in the Z-Lock collection?
- The Z-Lock collection covers three plug-to-connector families:C14 Locking (Z-Lock) → C13 — 10 A and 15 A, available in black, red, and blueC14 Locking (Z-Lock) → C15 — 15 A, for hot-condition equipment inletsC20 Locking (Z-Lock) → C19 — 20 A, 12 AWG SJT for higher-draw devicesLengths range from 0.6 m to 3.0 m (plus a 10 ft option on select SKUs).
- Can Z-Lock cords be used with standard PDUs — no special outlets required?
- Yes. The Z-Lock plug expands inside a standard IEC 60320 C13 or C19 outlet after insertion by spinning the rotary lock on the plug head. No proprietary PDU or modified outlet is needed. This makes Z-Lock a drop-in locking upgrade for existing data center infrastructure.