Skip to content

IEC 60320 C14 Plug Adapters

10–15 Amps125–250 voltsULcULCERoHS

Reference guide:IEC 60320 connector guide →

14

configurations

Easily adapt your C13 PDU Outlet to another configuration

When organizing your data rack, it can sometimes be challenging to have all identical power cables for your equipment. Sometimes you will require a unique plug type that is not offered on your Power Distribution Unit. This is where plug adapters come to save the day. With this product line series, you can easily adapt an IEC C13 Outlet to a variety of connector types for your convenience.

Adapt your plug type or provide an easier connection port

These plug adapters can not only be used to adapt the plug type, but they can also be used to angle the power connection, or even increase the number of outlets available. If you require an additional power outlet, you can plug a splitter adapter block into your receptacle and convert 1 C13 into 2. Additionally, if you need to route your cable in a 90-degree direction we offer angled C14 adapter blocks that can be a resourceful solution to a data cabinet with limited space.

Not sure which cord you need?

Answer a few quick questions and we’ll narrow it down for you.

Match by picture

The plugs and connectors in this collection

What each end is, what it mates with, and where to find every cord built on it.

  • IEC 60320 C14 plug

    Plug · IEC 60320

    IEC 60320 C14

    • 15 Amps
    • 250 volts

    On 13 of the cords here (87%)

    The IEC 60320 C14 is a grounded 3 Wire Plug rated up to 250V and 15 Amps. The C14 mates with a C13 outlet, typically found on Data Center/IT specific PDUs (Power Distribution Unit). The most common configuration for a C14 is in a jumper cable scenario, providing power from a PDU to IT Equipment.

    Mates with IEC 60320 C13 Outlet

  • IEC 60320 C13 connector

    Connector · IEC 60320

    IEC 60320 C13

    • 15 Amps
    • 125/250V

    On 2 of the cords here (13%)

    The IEC 60320 C13 is a grounded 3 Wire connector rated up to 250V and 15 Amps. The C13 mates with a C14 inlet, and is commonly used in a jumper cable scenario in IT Installations providing power from a PDU to a server, router, switch or other computing device. Most people know the C13 as 'the thing that plugs into my computer' because it is the standard connector used to power most desktop computers. In a desktop computer application, the most common cable is the NEMA 5-15P to C13, which connects your standard North American wall outlet to a desktop computer.

    Mates with IEC 60320 C14 Inlet

  • IEC 60320 C5 connector

    Connector · IEC 60320

    IEC 60320 C5

    • 10 Amps
    • 250 volts

    On 1 of the cords here (7%)

    The IEC 60320 C5 is a grounded 3 Wire connector rated up to 250V and 2.5 Amps Internationally or 125V and 10 Amps in North America. The C5 mates with a C6 inlet, and is commonly used for laptop power supplies, projectors, and some televisions. Being slightly smaller in size than the C13, the C5 can be a good choice for smaller appliances. This connector is sometimes referred to as a "Mickey Mouse" connector due to the shape of the connector looking similar to the kids television show character.

    Mates with IEC 60320 C6 Inlet

  • IEC 60320 C7 connector

    Connector · IEC 60320

    IEC 60320 C7

    • 10 Amps
    • 125 volts

    On 1 of the cords here (7%)

    The IEC 60320 C7 is an ungrounded 2 Wire connector rated up to 250V and 2.5 Amps Internationally or 125V and 10 Amps in North America. The C7 mates with a C8 inlet, and is commonly used for laptop power supplies, video game consoles, televisions, and other double-insulated small appliances. This connector is sometimes referred to as a "Figure-8" or "Shotgun" connector due to it's shape. A variation of the C7 exists, sometimes referred to as a C7P or C7 Polarized, although it is not documented in the IEC 60320 standard. The C7P has one square side and one circular side so the connector only mates with the inlet using the correct pin configuration.

    Mates with IEC 60320 C8 Inlet

  • IEC 60320 C15 connector

    Connector · IEC 60320

    IEC 60320 C15

    • 15 Amps
    • 125/250V

    On 1 of the cords here (7%)

    The IEC 320 C15 Power cable is used to power electrical devices that emit so much heat (intentionally or unintentionally) that they require a power connection that can withstand more than the 70 °C (158 °F) temperature rating of the standard C13. In combination with the C14 plug type, the use cases of this high-temperature cable are almost exclusively data center environments. This cable would most likely be found supplying a High-Powered Switch power from a rack-mounted PDU power supply source. If your equipment has a IEC320 C16 Inlet it should only be mated with the matching C15-Power Connector.

    Mates with IEC 60320 C16 Inlet

  • IEC 60320 C19 connector

    Connector · IEC 60320

    IEC 60320 C19

    • 20 Amps
    • 125/250V

    On 1 of the cords here (7%)

    The IEC 60320 C19 is a grounded 3 Wire connector rated up to 250V and 20 Amps. The C19 mates with a C20 inlet, and is commonly used in a jumper cable scenario in IT Installations providing power from a PDU to a server, router, switch or other computing device. The C19 is typically used in high powered blade server chassis, large network routers, and other IT equipment that draws more power than a standard C13 can accommodate.

    Mates with IEC 60320 C20 Inlet

About IEC 60320 C14 Plug Adapters

The C14 Type Plug Adapters can be used to adapt a C13 Outlet on a PDU. In circumstances where you need a quick fix to plug in a unique plug type, plug adapters can be especially useful. These adapters will not adapt voltage or amperage ratings, but they can adapt a configuration to allow you to plug your cable into a power source.

Current rating

10–15 Amps

Voltage rating

125–250 volts

Certifications & compliance

  • UL
  • cUL
  • CE
  • RoHS
  • Every cord we build is hi-pot tested
  • Same-day shipping by 2:30 PM ET
  • NET 30/60/90 for approved accounts
  • In-house engineering and compliance support

Frequently asked questions

What certifications do these power cords carry?
UL and cUL-listed cord sets across the catalog, with 30+ international approval marks (VDE, ENEC, PSE, SAA, CCC, KC and more) on country-specific cords. The approvals each part carries are listed on its product page; documentation is available from sales.
Do you require a minimum order quantity?
No. We sell from 1 cord to 100,000. Volume discounts apply automatically at quantity breaks — you'll see pricing tiers on every product page.
Can I get a custom length or color?
Yes. Custom lengths and non-standard colors are hand-terminated in our Connecticut shop — typically 3–4 business days from in-stock components. Call (860) 763-2100 or submit a quote request with your specs.
How fast does this ship?
In-stock orders placed by 2:30 PM ET ship the same day via FedEx or UPS. All standard configurations are stocked in East Windsor, CT.